TROUBLESHOOTING

WARNING: Turn off heater

and let cool before servicing. Only
a qualified service person should
service and repair heater.

CAUTION: Never use a wire,

needle, or similar object to clean
pilot. This can damage pilot unit.

Note:

For additional help, visit DESA

International’s technical service web site
at

www.desatech.com

.

Note:

All troubleshooting items are listed in

order of operation.

www.desatech.com

Continued

OBSERVED PROBLEM

Ignitor will not spark or pilot will not light

Pilot lights but will not stay lit

No gas to main burner, although wall switch
and valve are set to the ON position

Frequent main burner outage

POSSIBLE CAUSE

1. No gas supply, or equipment shutoff

valve is OFF

2. Air in gas line

3. Construction debris clogging pilot orifice

4. Low gas pressure

5. Kinked pilot line

6. Control valve knob is not opening

7. No power to unit or the ignition module

or power transformer is bad

1. Loose wiring on ignitor wire to ignition

module and/or poor ground to ignition
module

2. Pilot flame too low to sense

1. Wall switch wires defective or too long
2. Sensor, valve, or ignition module is not

operating

1. Pilot flame may be too low, causing

safety pilot to “drop out”

2. Vent may be blocked or restricted

REMEDY

1. Check to see if you have gas supply and

that the equipment shutoff valve is
opened

2. Repeat lighting procedure several times

to purge all air out of lines. If after re-
peated attempts appliance does not light
call for qualified service and repair

3. Remove debris and dirt, inspect and

clean any other possible obstructions

4. Contact your gas supplier to check pres-

sure

5. Have a qualified technician replace pi-

lot line

6. Replace control valve (Refer to Replace-

ment Parts, page 30)

7. Check that main power is on and that all

wire connections are made correctly to
the ignition model (see Wiring Diagram,
page 30). Check for 24 VAC at the sec-
ondary side of the transformer. If 24
VAC is present and the module does not
operate, have the module replaced oth-
erwise have the transformer replaced

1. Check ignitor wire connection. Refer to

wiring diagram (see Wiring Diagram,
page 30) and/or check ground wire to
ignition module

2. Clean and adjust pilot burner and check

gas supply and inlet pressure to unit

Note:

Have a qualified technician replace

pilot assembly if broken or corroded

1. Check electrical connections
2. Recheck problems 1 and 2

1. Clean and adjust pilot flame for maximum

flame impingement on sensor

2. Have vent inspected for blockage or

damage