True-rms Digital Multimeters

Making Measurements

33

To change whether the beeper sounds on shorts or opens, press
the softkey labeled Menu. Move the menu selector to the menu
item labeled Beeper and press the softkey labeled Short/O….
This beeper selection, Beep on Short or Beep on Open, is
displayed just above the continuity indicator. The continuity
beeper is always enabled when continuity mode if first entered.

To enable or disable the beeper for continuity, press the softkey
labeled Menu. Move the menu selector to the menu item labeled
Beeper and press the softkey labeled Beeper. The status of the
continuity beeper is displayed to the right of the resistance
reading with j when enabled and i when disabled. This
setting is independent of the Meter’s beeper enable/disable
setting in the setup menu.

Toggle between the continuity and ohms functions by pressing
softkey F3, which is always labeled with the alternate function.