Capacitance and diode test specifications – Fluke 289 User Manual

Page 83

Advertising
background image

True-rms Digital Multimeters

Detailed Specifications

73

Capacitance and Diode Test Specifications

Function Range Resolution

Accuracy

1 nF

[1]

0.001 nF

1 % + 5

10 nF

[1]

0.01 nF

1 % + 5

100 nF

[1]

0.1 nF

1 % + 5

1

μ

F 0.001

μ

F

1 % + 5

10

μ

F 0.01

μ

F

1 % + 5

100

μ

F

0.1

μ

F

1 % + 5

1000

μ

F 1

μ

F

1 % + 5

10 mF

0.01 mF

1 % + 5

Capacitance

100 mF

0.1 mF

2 % + 20

Diode Test

3.1 V

0.0001 V

1 % + 20

[1]

With a film capacitor or better, using relative mode (REL

Δ

) to zero residual.

Advertising
This manual is related to the following products:

287