7. Check to make sure that the power cord is

completely clear of the blower wheel and that

there are no other foreign objects in blower

wheel. Also double check all wire leads and

make sure wire routing is not pinched or in a

precarious position. Correct accordingly.

8. Turn on power to duplex outlet if previ-

ously turned off per the warning in column

1, page 19.

9. Plug in blower power cord to duplex outlet.

10. The blower will only run when the speed

control knob is in the ON position and the

thermal switch senses temperature after the

fireplace begins to heat up. The blower speed

can be adjusted by rotating the control knob.

To turn off, turn knob fully counterclockwise

until it clicks off. If the blower is ON and has

been running with the fireplace operating, the

blower will continue to run for a short time

after the fireplace has been turned off. As the

thermal switch cools down, the blower shuts

down automatically.

11. Peel off the backing paper and stick the sup-

plied wiring diagram decal on the firebox bot-

tom approximately 12" in front of the blower

(see Figure 28, page 20).

Blower Wiring Diagram

CAUTION: Label all wires

prior to disconnection when

servicing controls. Wiring errors

can cause improper and dan-

gerous operation. Verify proper

operation after servicing.

FIREPLACE

INSTALLATION

Continued

Figure 30 - Blower Wiring Diagram for

Thermostat-Controlled Models

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

INSTALLING GAS pIpING TO
FIREpLACE LOCATION

WARNING: A qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

CAUTION: For propane/LP

units, never connect fireplace

directly to the propane/LP supply.

This heater requires an external

regulator (not supplied). Install

the external regulator between the

fireplace and propane/LP supply.

WARNING: For natural

gas, never connect heater to

private (non-utility) gas wells.

This gas is commonly known

as wellhead gas.

Installation Items Needed

Before installing fireplace, make sure you have

the items listed below.

• external regulator (supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

• approved flexible gas line with gas connector

(if allowed by local codes)

* A CSA design-certified equipment shutoff

valve with 1/8" NPT tap is an acceptable alterna-

tive to test gauge connection. Purchase the CSA

design-certified equipment shutoff valve from

your retailer.

For propane/LP connection only, the installer

must supply an external regulator. The external

regulator will reduce incoming gas pressure. You

must reduce incoming gas pressure to between

11 and 14 inches of water. If you do not reduce

incoming gas pressure, fireplace regulator dam-

age could occur. Install external regulator with

the vent pointing down as shown in Figure 31,

page 22. Pointing the vent down protects it from

freezing rain or sleet.