1 safety characteristic data, Safety characteristic data – Pilz PNOZ mm0p-T User Manual
Page 25

Technical details
Operating Manual PNOZ mm0p-T
1002704-EN-01
25
Mechanical data
772010
Stripping length
9 mm
Dimensions
Height
100,0 mm
Width
45,0 mm
Depth
120,0 mm
Weight
230 g
The standards current on 2012-07 apply.
Safety characteristic data
Unit
Operating
mode
EN ISO
13849-1: 2006
PL
EN ISO
13849-1: 2006
Category
EN IEC 62061
SIL CL
PFH [1/h]
EN ISO
13849-1: 2006
TM [year]
Logic
CPU
–
PL e
Cat. 4
SIL CL 3
1,54E-09
20
Input
SC inputs
1-channel
PL d
Cat. 2
SIL CL 2
3,95E-09
20
SC inputs
2-channel
PL e
Cat. 4
SIL CL 3
4,61E-10
20
SC inputs
1-ch., pulsed
light beam
device
PL e
Cat. 4
SIL CL 3
3,95E-10
20
Output
SC outputs
1-channel
with ad-
vanced fault
detection
PL e
Cat. 4
SIL CL 3
7,65E-10
20
SC outputs
1-channel
PL d
Cat. 2
SIL CL 2
8,90E-10
20
SC outputs
2-channel
PL e
Cat. 4
SIL CL 3
7,86E-10
20
All the units used with a safety function must be considered wehn calculating the safety
characteristic data.
Information
A safety function´s SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function´s SIL/PL values.
8.1