Technical details
Operating Manual PNOZ m B0
1002660EN03
35
8.1
Safety characteristic data
Unit
Operating
mode
EN ISO
138491: 2008
PL
EN ISO
138491: 2008
Category
EN IEC 62061
SIL CL
EN IEC 62061
PFH
D
[1/h]
EN ISO
138491: 2008
T
M
[year]
Logic
CPU
–
PL e
Cat. 4
SIL CL 3
4,74E10
20
Expansion
right
–
PL e
Cat. 4
SIL CL 3
2,79E11
20
Input
SC inputs
1channel
PL d
Cat. 2
SIL CL 2
3,85E09
20
SC inputs
2channel
PL e
Cat. 4
SIL CL 3
7,95E11
20
SC inputs
1ch., pulsed
light barrier
PL e
Cat. 4
SIL CL 3
3,85E10
20
Output
SC outputs
1channel
with ad
vanced fault
detection
PL e
Cat. 4
SIL CL 3
1,66E11
20
SC outputs
1channel
PL d
Cat. 2
SIL CL 2
1,57E10
20
SC outputs
2channel
PL e
Cat. 4
SIL CL 3
1,29E10
20
All the units used within a safety function must be considered when calculating the safety
characteristic data.
INFORMATION
A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use