4 function description, 1 module features, 1 function description – Pilz PSSu E F 4DO 0.5 User Manual

Page 13: Section 4, Function description, Module features, 4function description

Advertising
background image

Function description

Operating Manual PSSu E F 4DO 0.5(­T)(­R)
21316­EN­05

13

4

Function description

4.1

Module features

4.1.1

Function description

Module supply

}

The module supply provides the module with voltage.

Signals at the output

}

“0” signal (0 V) at the output:

}

Output is high impedance

–

No current to the load

}

“1” signal (+24 V) at the output:

}

Output is low impedance

–

Current is supplied to the load

Periphery supply

}

The module routes the periphery supply from the module bus to the base module ter­
minals.

}

The periphery supply is used to supply the outputs.

Outputs

}

The head module sets the output status via the module bus.

}

The max. capacity at an output depends on the load (see characteristic). Connecting a
higher capacity may lead to an error.

}

Operation with electronic contactors has not been tested and may lead to errors.
Please contact our Customer Support team if you are using electronic contactors.

Output test

}

Outputs that are switched on are checked via regular off tests.

}

Test pulses for outputs that are switched on: see Technical Details

–

Outputs that are switched on are switched off for the duration of the test pulse.

–

The load must not switch off because of the test.

}

Outputs that are switched off are checked via regular on tests.

}

Test pulses for outputs that are switched off: see Technical Details

–

Outputs that are switched off are switched on for the duration of the test pulse.

–

The load must not switch on because of the test.

Excluding individual outputs from the output test:

}

If a plant is particularly sensitive to the test pulses, they may be switched off for indi­
vidual outputs.

}

The test must be replaced by other measures, depending on the safety requirement.

}

When test pulses are switched off:

}

The correct switch status is always checked.