Wiring
Operating Manual PSSu K F FCU
1002391-EN-04
27
Wiring
General wiring guidelines
Please note:
}
Signal lines do not have to be shielded.
}
The outputs do not need suppression for inductive loads.
}
Use copper wiring.
Connectors' mechanical connection
Please note:
}
The conductor cross section on the spring-loaded terminals without ferrules is 0,20 -
1,00 mm², 22 - 18 AWG.
}
If you are using multi-core or fine-core cables we recommend ferrules in accordance
with DIN 46228/Part 1 or DIN 46228/Part 4, 0.2 ... 1 mm
2
. To crimp the ferrules we rec-
ommend crimping pliers (crimp form A) conforming to EN 60947-1, such as the PZ 6/5
from Weidmüller, for example.
}
Terminal points per connection: 1
}
Stripping length: 8 mm