Altera Mentor Verification IP Altera Edition AMBA AXI3/4TM User Manual

Page 694

Advertising
background image

Mentor VIP AE AXI3/4 User Guide, V10.2b

674

Assertions
AXI3 Assertions

September 2013

Error
Code

Error Name

Description

Property
Ref

AXI3-
60130

AXI_WRITE_DATA_UNKN_ON_
INVALID_LANE

On a lane whose strobe is 0, WDATA has an
X or Z value.

A2.3

AXI3-
60131

AXI_WRITE_DATA_UNKN_ON_
VALID_LANE

On a lane whose strobe is 1, WDATA has an
X or Z value.

A2.3

AXI3-
60132

AXI_RESERVED_AWLOCK_
ENCODING

The reserved encoding of 2'b11 should not
be used for AWLOCK.

A7.4

AXI3-
60133

AXI_WRITE_STROBE_ON_INVALID_
BYTE_LANES

Write strobe(s) incorrect for the address/size
of a fixed transfer.

A2.3

AXI3-
60134

AXI_WSTRB_CHANGED_BEFORE_
WREADY

The value of WSTRB has changed from its
initial value between the time WVALID was
asserted, and before WREADY was
asserted.

A3.2.1

AXI3-
60135

AXI_WSTRB_UNKN

WSTRB has an X or Z value.

A2.3

AXI3-
60136

AXI_WUSER_CHANGED_BEFORE_
WREADY

The value of WUSER has changed from its
initial value between the time WVALID was
asserted, and before WREADY was
asserted.

A3.2.1

AXI3-
60137

AXI_WUSER_UNKN

WUSER has an X or Z value.

A2.3

AXI3-
60138

AXI_WVALID_DEASSERTED_
BEFORE_WREADY

WVALID has been de-asserted before
WREADY was asserted.

A3.2.1

AXI3-
60139

AXI_WVALID_HIGH_ON_FIRST_
CLOCK_AFTER_RESET

A master interface must begin driving
WVALID high only at a rising clock edge after
ARESETn is HIGH.

A3.1.2

AXI3-
60140

AXI_WVALID_UNKN

WVALID has an X or Z value.

A2.3

AXI3-
60141

AXI_ADDR_ACROSS_4K_WITHIN_
LOCKED_WRITE_TRANSACTION

Transactions in a locked write sequence
should be in the same 4K address boundary.

A7.3

AXI3-
60142

AXI_ADDR_ACROSS_4K_WITHIN_
LOCKED_READ_TRANSACTION

Transactions in a locked read sequence
should be in the same 4K address boundary.

A7.3

AXI3-
60143

AXI_AWID_CHANGED_WITHIN_
LOCKED_TRANSACTION

Master should not change the AWID signal in
the locked transaction.

A7.3

AXI3-
60144

AXI_ARID_CHANGED_WITHIN_
LOCKED_TRANSACTION

Master should not change the ARID signal in
the locked transaction.

A7.3

AXI3-
60145

AXI_AWPROT_CHANGED_WITHIN_
LOCKED_TRANSACTION

Master should not change the AWPROT
signal in the locked transaction.

A7.3

Table A-1. AXI3 Assertions (cont.)

Advertising