Fireplace installation – Desa GL36CRP User Manual

Page 10

Advertising
background image

www.desatech.com

112301-01D

10

2. Prepare incoming gas line and check with local

codes regarding use of Teflon tape. Complete

gas line installation by connecting incoming

gas line with flexible gas line. Secure tightly

with wrench. Do not overtighten.

WARNING: All gas piping

and connections must be tested

for leaks after the installation is

completed.
After ensuring that the gas valve

is on, apply a commercial leak

detection solution to all con-

nections and joints. If bubbles

appear, leaks can be detected

and corrected.
Do not use an open flame for leak

testing and do not operate any

appliance if a leak is detected.

LOG SET PLACEMENT

Carefully remove log set from packaging. Place

the two bottom logs over grate and align with pins.

Place three loose logs, or twigs, onto alignment

pins on two bottom logs (see Figure 16).

FIREPLACE

INSTALLATION

Continued

FIREPLACE FACING

Any noncombustible material may be used for

facing (glass, tile, brick, etc.) as long as the proper

clearances are adhered to and the fireplace open-

ings are not blocked or obstructed in any way. See

Clearances, page 6, and Figure 17.

Use only heat resistant, noncombustible mortar

or adhesive when securing facing material to the

front of the fireplace.

Figure 16 - Log Placement

GLASS DOOR

When fireplace is in operation, glass doors must

be either fully open or fully closed position (see

Figure 18).

Figure 17 - Fireplace Facing Material

Noncombustible
Facing Material

Do Not
Block
Effective
Opening

"L" Shaped
Metal Support

Noncombustible
Facing Material

Bottom Logs

Top Logs (Twigs)

Figure 18 - Glass Doors Shown Fully

Open

Glass Doors Must be Fully Open
(as Shown) or Fully Closed when
Appliance is in Operation

Right
Corner
Opening

Left
Corner
Opening

Advertising
This manual is related to the following products: