Continued

This unit has been tested for installation at high

altitude in accordance with Canadian test stan-

dard CAN/CGA-2.17. Higher altitudes affect the

atmospheric pressure and heat valve of gaseous

fuels. When installing this unit at high altitudes,

the rated input will be lower than at sea level. The

lowered oxygen content in the air and the lowered

gas density require installation of a different size

orifice in order to achieve clean combustion of

the unit. Consult the unit data plate for the proper

high-altitude orifice size. Fill out the information

sticker attached to the unit when field converting.

See Specifications, page 14, when derating.

Figure 12 - Millivolt Control Valve

Figure 13 - Electronic Control Valve

ON/OFF
Knob

Pilot
Adjustment
Cap

Pilot Gas Line
Do Not Kink

Inlet
Pressure

Outlet
Pressure

To Main
Burner

To Pilot
Burner

E

A

From
Gas
Supply

To
Main
Burner

Inlet
Pressure

Outlet
Pressure

A manual shutoff valve has been included in the

appliance’s gas supply system. You may consider

installing an extra gas shutoff valve outside the

appliance’s enclosure (check with local codes)

where it can be accessed more conveniently with a

key through a wall as shown in Figure 14.

Route a 1/2" NPT gas line towards appliance

coming in from back of appliance. If installation

permits, you may alternately route your incoming

gas line from bottom of appliance toward either

end. It is recommended to route gas pipe from back

of fireplace if possible.

CAUTION: Do not kink flex-

ible gas line.

CAUTION: Compounds used

on threaded joints of gas piping

shall be resistant to the action of

Liquefied Petroleum (propane/

LP) and should be applied lightly

to ensure excess sealant does

not enter the gas line.

1. Install a sediment trap between incoming gas

line and gas control valve (see Figure 15).

Sediment trap should extend down center of

pipe. Refer to your local codes.

Key

Extension

Shutoff
Valve

Figure 14 - Typical Exterior Wall Gas

Shutoff Installation

GAS LINE HOOK-UP

WARNING: Gas line hookup

should be done by your gas

supplier or a qualified service

person.

WARNING: Before you pro-

ceed, make sure your gas supply

is OFF.

Figure 15 - Sediment Trap

3" Min.

(76 mm)

Side W

all

Of Appliance

Incoming 1/2" Gas Line
Permitted by Local Codes

Sediment
Trap (Not
Supplied)