FIREPLACE

INSTALLATION

Continued

FRAMING

Construct framing using dimensions shown if

Figures 6, 7 and 8. (Use the figure applicable to

your application.) Figure 6 shows the framing

dimensions prior to having the appliance in place.

If installing on a platform, platform must be solid,

flat and fully supported (see Figure 7). Once the unit

has been fitted, bring studs in against nailing flanges

located on the side of the appliance making sure

a 1" clearance is maintained as shown in Figure 8.

If the fireplace is to be installed directly on carpeting,

tile (other than ceramic) or any combustible mate-

rial other than wood flooring the fireplace must be

installed upon a metal or wood panel extending the

full width and depth of the fireplace.

Figure 6 - Framing Dimensions Prior to

Placing Appliance

Figure 8 - Securing Appliance with

Nailing Flanges

52

3

/

4

"

Min.

41"

25

5

/

8

"

VENT PIPE INSTALLATION

A 6" B-1 type gas vent pipe is a double wall, vent-

ing system (not supplied) which must be installed

during rough framing of the appliance. Any B-1

type gas vent system may be used for proper vent-

ing as long as the vent system is installed per the

vent manufacturer’s recommendations.

DESA supplies this appliance with a tapered starter

pipe for a snug fit. Slide B-1 type vent pipe over

this starter pipe until vent pipe is fully seated.

Secure this first section of B-vent pipe by strap-

ping the connector around the vent pipe and then

tightening the strap with any 1/8" nut and bolt (see

Figure 9). Note: Visually inspect for proper vent

connection by looking inside top of appliance. If

connection does not appear to be correct, contact

your local service technician.

Figure 9 - Installing B-Vent Pipe

Nailing
Flange

1" Min. to
Combustibles

Prepared
Framing

Nails or
Screws

B-1 Type
Vent (Not
Supplied)

Strap
(Fasten with
1/8" Screw
or Bolt)

52

3

/

4

"

Min.

24"

*

Figure 7 - Framing Dimensions Prior to

Placing Appliance Using a Platform

*As required by design as

long as ceiling clearance is

maintained

Advertising