Fireplace installation, Continued optional outside air kit (model ak-4), Wall switch installation – Desa GL36CRP User Manual

Page 8: Gas supply testing

Advertising
background image

www.desatech.com

112301-01D

8

FIREPLACE

INSTALLATION

Continued

OPTIONAL OUTSIDE AIR KIT
(MODEL AK-4)

The installation of an outside air kit should be

completed during the rough framing of the fire-

place due to the nature of it's location. Outside

combustion air is accessed through a vented

crawl space.

CAUTION: Air inlet ducts

must not be terminated in an

attic space.

Avoid installing outside air eyebrow in areas where

inlet opening may be blocked by snow, bushes or

other obstacles (see Figure 10).

The maximum height for the air inlet termination

cannot exceed 3 feet below the B-vent termination

exhaust height.

Figure 10 - Outside Air Kit

Secure to Collars with Duct Tape or
Screws

Air Inlet
Location
Must Allow
For Bushes
or Snow

Vent Hood
Required for
Wall Installation

Air Inlet
Eyebrow

Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)

WALL SWITCH INSTALLATION

The electronic version uses a 24 VAC current sup-

plied from a transformer mounted on the ignition

module and is prewired for easy connection to a

wall switch. The millivolt version uses a self-gen-

erated millivolt current that allows you to activate

the gas control valve directly without the use of

normal household electricity. Both versions are

supplied with a wall switch kit for ready connec-

tion and mounting.

CAUTION: Do not connect

the remote wall switch to a

regular 120v power source! Gas

valve will be damaged beyond

repair.

Connect 18 ga. wires from wall switch to gas

control valve terminals marked TH and TPTH

or to ignition module using pigtails and wire nut

connectors supplied with appliance.
Note:

If any of the original supplied wire must be

replaced, use type 18 AWG-105 C (25 ft. maxi-

mum length) or equivalent only.

CAUTION: Due to high tem-

peratures, make sure wires are

not touching upper firebox.

GAS SUPPLY TESTING

Note:

This section is intended as a guide for quali-

fied technicians installing gas to this appliance.

CAUTION: Do not connect

appliance before pressure test-

ing gas piping. Damage to gas

valve may result and an unsafe

condition may be caused.

The appliance and its individual shutoff valve must

be disconnected from the gas supply piping system

during any pressure testing of that system at test

pressures in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas sup-

ply piping system by closing its individual manual

shutoff valve during any pressure testing of the gas

supply piping system at test pressures equal to or

less than 1/2 psig (3.5 kPa).

Figure 11 - Wall Switch Installation

O

F

P

IL

O

T

ON

F

T

O

I

P L

7

TP

T

H

TP

TH

Wall Switch

(Supplied)

Back View

To Thermopile

Route Millivolt Wires
(Supplied) Through
Electrical Conduit Bushing