OPERATING FIREPLACE

MILLIVOLT MODELS

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas

supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the

knob will not push in or turn by hand, don’t

try to repair it. Call a qualified service tech-

nician or gas supplier. Force or attempted

repair may result in a fire or explosion.

D. Do not use this appliance if any part has

been under water. Immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control which

has been under water.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information above.

2. Turn wall switch to the OFF position.

3. Turn off all electric power to the appliance.

4. Open control access panel.

5. Push in gas control knob and turn clock-

wise

to the OFF position (see

Figure 19). Note: It is recommended that

you maintain the gas control knob in the

full OFF position during lengthy periods

of seasonal non usage.

6. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information in column 1. If you don’t

smell gas, go to the next step.

7. Turn control knob counterclockwise

to the PILOT position.

8. Push in control knob all the way and hold

in. Immediately light the pilot by pressing

the red ignitor button until a flame ap-

pears. Continue to hold the control knob

in for about (1) minute after the pilot is lit.

Release knob and it will pop back up. Pilot

should remain lit. If it goes out, repeat steps

5 through 7. The pilot is located by main

burner (see Figure 20).

• If knob does not pop up when released,

stop and immediately call your service

technician or gas supplier.

• If the pilot will not stay lit after several

tries, turn the gas control knob to OFF

and call your service technician or gas

supplier.

9. Turn gas control knob counterclockwise

to ON. Knob can be turned to ON

only if the control knob is popped out.

10. Replace control access panel.

11. Turn on all electric power to the appliance.

Figure 19 - Millivolt Control Valve

Position Indicator

Gas Control Knob

Figure 20 - Pilot

Thermopile

Pilot
Burner

Ignitor