Ip - immediate position, Is - input status, Ja - jog acceleration – Applied Motion 1240i User Manual

Page 19: Jd - jog disable, Je - jog enable, Js - jog speed

Advertising
background image

SCL Software Manual

19

920-0010 rev B

9/26/07

Example:
You send

Drive sends

IL1

output 1 goes low immediately

IL2

output 2 goes low immediately

See also: IH, SO

IP – Immediate Position

Requests present absolute position, in hex. (Value is in hex because conversion to ascii of another
format would tax the CPU enough to interfere with a move in program. Application programs can
easily convert a hex value to integer.)

Example:
You send

Drive sends

Notes

IP

IP=00002710

abs position is 10,000 steps

IS – Input Status

Requests immediate status of all 8 inputs.

Example:
You send

Drive sends

Notes

IS

IS=00000000

all 8 inputs are low (closed)

IS

IS=11111111

all 8 inputs are high (open)

IS

IS=00000001

input 1 is high

IS

IS=10000000

input 8 is high

JA – Jog Acceleration

Sets accel/decel rate for jog moves in rev/sec/sec. Sending JA with no number causes drive to re-
spond with present jog accel/decel rate. Range is 1 – 3000.
Affects: WI (jogging)
See also: JS

Example:
You send

Drive sends

JA100

nothing

JA

JA=100

JD – Jog Disable

Disables jog inputs (normally active during WI instructions)

JE – Jog Enable

Enables jog inputs (active during WI instructions)

JS – Jog Speed

Sets speed for jog moves in rev/sec. Sending JS with no number causes drive to respond with
present jog speed. Range is .025 – 50.
Affects: WI (jogging)
See also: JA

IS= 1 1 1 1 1 1 1 1

IN1
IN2
IN3
IN4
IN5(cw jog)
IN6(ccw jog)
IN7(cw limit)
IN8(ccw limit)

Advertising
This manual is related to the following products: