3 x3/x4/x5/x6 digital input – Applied Motion TSM17Q-1AG User Manual

Page 18

Advertising
background image

18

Rev. A

920-0084

TSM17S/Q Hardware Manual

3.3.3 X3/X4/X5/X6 Digital Input

While the STEP and DIR inputs are designed for high-speed digital input operation, the X3/X4/

X5/X6 input are designed for low speed digital input operation between 5 and 24 volts optically

Isolated Single-ended input.

What is COM?

“Common” is an electronics term for an electrical connection to a common voltage. Sometimes

“common” means the same thing as “ground”, but not always. In the case of the TSM17 drives, if

you are using sourcing (PNP) input signals, then you will want to connect COM to ground (power

supply -). If you are using sinking (NPN) signals, then COM must connect to power supply +.

Note: If current is flowing into or out of an input, the logic state of that input is low or

closed. If no current is flowing, or the input is not connected, the logic state is high or

open.

The diagrams below show how to connect X3/X4/X5/X6 input to various commonly used devices.

5-24VDC

0VDC

XCOM

X3

X4

X5

X6

User Control

Drives

5-24VDC

XCOM

X3

X4

Drives

0VDC

+

-

NPN

Sensor

5-24VDC

XCOM

X3

Drives

+

-

PNP

Sensor

0VDC

Advertising