3.3.5 AIN Input

The TSM17S/Q drives have an analog input (AIN) which can accept a signal range of 0 to 5 volts.

The drive can be configured to operate at a speed or position that is proportional to the analog

signal. Use the Step-Servo Quick Tuner software to set the signal range, offset, dead-band and

filter frequency. The TSM17S/Q provides a +5 volt/100mA limit voltage supply that can be used to

power external devices such as potentiometers. It is not the most accurate supply for reference,

for more precise readings use an external supply that can provide the desired accuracy.