3 current – Applied Motion TSM17Q-1AG User Manual

Page 8

Advertising
background image

8

Rev. A

920-0084

TSM17S/Q Hardware Manual

2.3.3 Current

The maximum supply currents required by the TSM17S/Q are shown in the charts below at

different power supply voltage inputs. The TSM17S/Q power supply current is lower than the

winding currents because it uses switching amplifiers to convert a high voltage and low current

into lower voltage and higher current. The more the power supply voltage exceeds the motor

voltage, the less current will be required from the power supply.

It is important to note that the current draw is significantly different at higher speeds depending

on the torque load to the motor. Estimating how much current is necessary may require a good

analysis of the load the motor will encounter.

0

0.5

1

1.5

0

0.1

0.2

0.3

0.4

0

10

20

30

40

50

TSM17

-1

G 12V Power

To

rq

ue

(N

.m

)

Speed(RPS)

A

m

ps

Continuous

Torque

Boost

Supply Current

Full Load

No Load

0

0.5

1

1.5

0

0.1

0.2

0.3

0.4

0

10

20

30

40

50

TSM17

-1

G 24V Power

To

rq

ue

(N

.m

)

Speed(RPS)

A

m

ps

Continuous

Torque

Boost

Supply Current

Full Load

No Load

Advertising