3.3.6 Programmable Output Y1/Y2/Y3

The TSM17S/Q drives feature three optically isolated digital outputs (Y1 to Y3). Y1, Y2 and Y3

share a common terminal YCOM.
• Y1 can be set to signal a fault condition.
• Y2 can be set to indicate whether the motor is in position(dynamic).
• Y3 can be set to control a motor brake.
These outputs can also be turned on and off by program instructions like Set Output (SO). The
output can be used to drive LEDs, relays and the inputs of other electronic devices like PLCs and
counters. Diagrams of various connection types follow.
Do not connect the outputs to more than 30 volts. The current through each output terminal must
not exceed 100mA.