Fireplace installation – Desa (V)VC36N Series User Manual

Page 24

Advertising
background image

www.desatech.com

116200-01H

24

pRESSURE TESTING FIREpLACE GAS
CONNECTIONS

1. Open equipment shutoff valve (see Figure 34,

page 23).

2. Open propane/LP supply tank valve for

propane/LP fireplace or main gas valve

located on or near gas meter for natural gas

fireplace.

3. Make sure control knob of fireplace is in the

OFF position.

4. Check all joints from equipment shutoff valve

to gas valve (see Figure 35 or Figure 36, page

23). Apply noncorrosive leak detection fluid

to all joints. Bubbles forming show a leak.

Correct all leaks at once.

5. Light fireplace (see Operating Fireplace, page

27). Check all other internal joints for leaks.

6. Turn off fireplace (see To Turn Off Gas to Ap-

pliance, page 28).

INSTALLING OpTIONAL WALL
MOUNT SWITCH - GWMS2

1. Connect one terminal of 25 ft. wire for the wall

switch to the TPTH terminal on the valve. Con-

nect remaining wire terminal to the TH terminal

on the valve. Make sure that the wire terminals

are in the positions on the unit as pictured in

Figure 37. If wires are not connected as shown

the switch will not work.

2. Route the 25 ft. wire through openings pro-

vided on the sides of the burner system to a

convenient location to mount your switch.

3. Connect one bare wire end to each of the

terminals of GWMS2 wall switch.

4. Install the wall switch and cover in the wall.

FIREPLACE

INSTALLATION

Continued

Figure 37 - Connecting Wall Switch to

Control Valve

To Wall Switch
Accessory

INSTALLING OpTIONAL WIRELESS
HAND-HELD REMOTE CONTROL
HRC100 AND HRC200 SERIES

NOTICE: Use only alkaline bat-

teries (not included).

Installing Remote Receiver

1. Open bottom louver and locate the switch

bracket on the right.

2. Unscrew the switch bracket. Lean bracket

forward so you are able to access the back of

the remote receiver.

3. Locate the battery clip mounted on the back of

the receiver. Slide a 9-volt alkaline battery (not

included) through the clip (see Figure 38).

4. Attach the terminal wires to the battery.

5. Connect wires from receiver to TH and TPTH

to control valve (see Figure 39).

6. Replace the switch bracket.

Figure 38 - Attaching Alkaline Battery to

Receiver

Figure 39 - Control Valve Terminals

To Optional
Remote
Accessory

9-Volt
Alkaline
Battery

Receiver

Terminal
Wires

Battery Clip

To Wall
Thermostat

Advertising