OPERATING FIREPLACE

Continued

ON/OFF SERIES MODEL HRC100

Hold the control button on the hand-held

remote until burner turns on. Hold the con-

trol button again until burner turns off (see

Figure 47).
TO LOCK

press both buttons on hand-held

remote control until light stops flashing. Hand-

held remote control is now locked. If the fire is

on it will be turned off automatically. In the

locked state, the light will not light up when

any button is pressed.
TO UNLOCK

press both buttons together

on hand-held remote control until the light

stops flashing. The hand-held remote is now

unlocked.

Figure 47 - On/Off Hand-Held Remote

Control Unit HRC100

Control

Button

Indicator

Light

THERMOSTAT SERIES MODEL
HRC200

The hand-held remote can be operated using

either the manual mode (MANU) or thermo-

static mode (AUTO) (see Figure 48). To select

Fahrenheit/Centigrade mode display, carefully

press the ˚C/˚F mode button with the end of a

paper clip or similar blunt object.
Manual Mode

1. Press the POWER and LOCK buttons

together to turn on the hand-held remote

control.

2. Press the MANU button to turn on the

fireplace.

3. Press the POWER and LOCK buttons

together to turn off the fireplace.

Auto (Thermostatic) Mode

1. Press the POWER and LOCK buttons

together to turn on the hand-held remote

control.

2. Press AUTO button to select this mode.

3. Set the desired room temperature by

pressing the TEMP + or - buttons.

4. Press the POWER and LOCK buttons

together to turn off the fireplace

Note:

Do not leave the hand-held remote in

the AUTO mode close to the fireplace. The

radiant heat from the fireplace will turn off the

fireplace. Ideally, place the hand-held remote

in the center of the room facing towards the

fireplace.
Note:

Do not hold the hand-held remote for

a long time. Body temperature will affect its

operation in the AUTO mode.

Figure 48 - Thermostat Hand-Held

Remote Control Unit HRC200

LOCK

MANU

AUTO

ºC/ºF

TEMP

POWER

ROOM
TEMP

SET
TEMP

AUTO

Turns
Hand-Held
Remote On
or Off and
Allows You
to Choose
the Manual
Setting

Selects
AUTO
Mode

°C/°F Mode
Button

Locks
System to
Prevent
Accidental
Ignition

Turns
Burners
On or Off

Increases or
Decreases
Room
Temperature in
AUTO Mode

Digital Display Shows
Temperature and Settings

Safety Features

When away from home for an extended period

of time or as a child safety feature to prevent

accidental ignition of the fireplace, the receiver

ON/OFF/REMOTE switch should be in the

OFF position.
Auto Shutoff Feature

1. If the average room temperature exceeds

82 degrees Fahrenheit (28 degrees Centi-

grade), the hand-held remote control will

perform a safety override and shut the

fireplace off. This feature is not available

in the MANU mode.

2. The receiver continuously receives signals

from the hand-held remote to control the

room temperature. If the hand-held remote

is misplaced, obstructed or for any reason

cannot transmit to the receiver, the receiver

will shut off the fireplace after 8 minutes.