7. Turn gas control knob counterclockwise

to “PILOT”. (see Figure 45)

8. Push in gas control knob all the way and

hold. Immediately light the pilot by repeat-

edly depressing the piezo spark ignitor until

a flame appears. Continue to hold for about

one (1) minute after the pilot is lit. Release

gas control knob and it will pop back. Pilot

should remain lit. If it goes out, repeat steps

5 through 8.

• If gas control knob does not pop up when

released, stop and immediately call your

service technician or gas supplier.

• If the pilot will not stay lit after several tries,

turn the gas control knob to “OFF” and call

your service technician or gas supplier.

9. Turn on all electric power to the fireplace.
10. Turn gas control knob counterclockwise

to “ON”.

11. This valve is equipped with a HI/LO fea-

ture. Set fireplace input as desired.

12. Close lower louver panel.

OPERATING FIREPLACE

Continued

O

F

F

PILOT

LO

IH

O

N

Figure 45 - Control Valve

Piezo Ignitor

Gas Control
Knob

Variable Control Knob

TO TURN OFF GAS

TO AppLIANCE

1. Open lower louver panel.

2. Set selector switch in the OFF position to

prevent draining battery.

3. Turn off all electrical power to the appliance

if service is to be performed.

4. Push in gas control knob slightly and turn

clockwise

to “OFF”.

5. Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot

lit by doing one of the following:

1. Turn gas control knob clockwise

to the

PILOT position.

2. Set selector switch in the OFF position.

MANUAL LIGHTING

pROCEDURE

1. Remove glass door (see Removing/Replacing

Glass Door, page 25).

2. Follow steps 1 through 8 under Lighting In-

structions, page 27.

3. Depress gas control knob and light pilot

with match.

4. Keep gas control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,

release gas control knob. Follow steps 9

through 12 under Lighting Instructions.

5. Replace glass door (see Removing/Replacing

Glass Door, page 25).

OpTIONAL HAND-HELD

REMOTE OpERATION

Note:

All remote control accessories must be

purchased separately (see Accessories, page

42). Follow instructions included with the

remote control.

NOTICE: You must light the pilot

before using the hand-held re-

mote control unit. See Lighting

Instructions, page 27.

After lighting, let pilot flame burn for about

one minute. Turn control knob to ON position.

Adjust flame adjustment knob anywhere be-

tween HI and LO. Slide the selector switch to

the REMOTE position (see Figure 46). Note:

The burner may light if hand-held remote was

on when selector switch was last turned off.

You can now turn the burner on and off with

the hand-held remote control unit.
IMPORTANT:

Do not leave the selector switch

in the REMOTE or ON position when the pilot

is not lit. This will drain the battery.

OF

F

PIL

O

T

LO

IH

ON

OFF

REMOTE

ON

OFF

O

N

Blower Control Knob
(Optional Accessory)

Variable
Control
Knob

Selector Switch in
Remote Position

Gas Control Knob
in ON Position

Figure 46 - Setting the Selector Switch,

Gas Control Knob and Variable Control

Knob for Remote Operation