10. Route power cord out of the cabinet by in-

serting it through the bushing on the outer cas-
ing (see Figure 15, page 15). Plug fan kit into
120-Volt grounded power supply and test op-
eration. Note: When switch is in the AUTO
position, the fan will start after the fireplace
has run for a few moments. The fan will con-
tinue to run for several moments after the fire-
place has been turned off. When switch is in
the ON position, the fan will run until turned
to OFF. Reinstall upper louver (see Figure 14,
page 14). Close lower louver door.

INSTALLATION

Continued

Red

Red

Fan Switch

(Auto/Off/On)

Blue

Blue

Thermostat

Switch

(N.O.)

Green

White

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

3

Auto

Figure 18 - Wiring Diagram For Blower

Accessory Built-In Installation

For Built-In Installation

WARNING: A licensed elec-

trician must connect the wiring
harness to electrical supply fol-
lowing all local codes. Electri-
cian must provide a clamp on
the box cover to secure the wir-
ing. Wiring should be routed
through the bushing in the hole
on the outer casing of fireplace.

1. Locate fan switch cover. Remove bottom

screw to remove back portion of the cover (see
Figure 17).

2. Install a snap bushing found in hardware kit

into one of the holes on rear of fan switch cover.
The other hole is for a strain relief clamp (not
supplied) to secure incoming electrical supply.

3. Follow steps 3 through 7 in Installing Blower

Accessory, page 14.

4. A licensed electrician must follow the wiring

diagram to connect incoming electrical sup-
ply to fan kit wiring harness (see Figure 18).

Figure 17 - Installing Switch Plate to Fan

Switch Cover

Switch
Cover
Screw

Screw

Rear -
Fan
Switch
Cover

Front - Fan
Switch Cover

Switch Plate

5. Install the switch plate on front of fan

switch cover with 2 #10 screws provided
(see Figure 17). Using screw removed in
step one, reconnect front and rear of fan
switch cover.

6. Plug power cord to the outlet receptacle (not

provided) as shown in Figure 19, page 17. Wind
extra cable of power cord and tie it up with the
plastic wire strap (see Figure 19, page 17). Set
the cable bundle between the fan switch box
and outer casing, away from the burner.

7. Test to make sure the blower is working

properly.

8. Reinstall upper louver (see Figure 14, page

14) and close lower louver.

Extension Cord
Use extension cord if needed. The cord must have a
three-prong, grounding plug and a three-hole recep-
tacle. Make sure cord is in good shape. It must be
heavy enough to carry the current needed. An under-
sized cord will cause a drop in line voltage. This will
result in loss of power and overheating. Use a No.
16 AWG cord for lengths less than 50 feet.