CLEANING AND

MAINTENANCE

WARNING: Turn off fireplace

and let cool before cleaning.

CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of fireplace
clean. Inspect these areas of fire-
place before each use. Have fire-
place inspected yearly by a quali-
fied service person. Fireplace may
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, bedding material, etc.

WARNING: Failure to keep

the primary air opening(s) of the
burner(s) clean may result in
sooting and property damage.

BURNER INJECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount
of air to mix with the gas. This provides a clean
burning flame. Keep these holes clear of dust, dirt,
lint, and pet hair. Clean these air inlet holes prior to
each heating season. Blocked air holes will create
soot. We recommend that you clean the unit every
three months during operation and have fireplace
inspected yearly by a qualified service person.
We also recommend that you keep the burner tube
and pilot assembly clean and free of dust and dirt.
To clean these parts we recommend using com-
pressed air no greater than 30 PSI. Your local com-
puter store, hardware store, or home center may
carry compressed air in a can. You can use a
vacuum cleaner in the blow position. If using com-
pressed air in a can, please follow the directions
on the can. If you don't follow directions on the
can, you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow

the unit to cool for at least thirty minutes.

2. Inspect burner, pilot, and primary air inlet

holes on injector holder for dust and dirt (see
Figure 51).

3. Blow air through the ports/slots and holes in

the burner.

4. Check the injector holder located at the end

of the burner tube again. Remove any large
particles of dust, dirt, lint, or pet hair with a
soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the in-

jector holder.

6. In case any large clumps of dust have now been

pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about
two inches from where the pilot flame comes out
of the pilot assembly (see Figures 52 or 53 depend-
ing on model). With the unit off, lightly blow air
through the air inlet hole. You may blow through a
drinking straw if compressed air is not available.

Figure 51 - Injector Holder On Outlet

Burner Tube

Burner
Tube

Injector
Holder

Primary Air
Inlet Holes

Ports/Slots

Figure 52 - Pilot Inlet Air Hole

(Propane/LP Gas)

Pilot Assembly

Pilot Air
Inlet Hole

Pilot Assembly

Pilot Air
Inlet Hole

Figure 53 - Pilot Inlet Air Hole

(Natural Gas)

LOG SET

• If you remove one-piece log set for cleaning,

refer to Installing Log Set and Screen, page 23,
for placement instructions.

• Replace log set if broken or chipped (dime-sized

or larger).

CABINET

Air Passageways
• Use a vacuum cleaner or pressurized air to clean.

Exterior
• Use a soft cloth dampened with a mild soap and

water mixture. Wipe the cabinet to remove dust.

Advertising