TROUBLESHOOTIING

WARNING: Turn off and unplug fireplace and let cool before

servicing. Only a qualified service person should service and repair
fireplace.

CAUTION: Never use a wire, needle, or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note:

All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

1. Ignitor electrode not con-

nected to ignitor cable

2. Ignitor cable pinched or wet

3. Broken ignitor cable
4. Bad ignitor
5. Ignitor electrode positioned

wrong

6. Ignitor electrode broken
7. Battery not installed, battery

power low, or battery not in-
stalled correctly

1. Gas supply turned off or

equipment shutoff valve
closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

4. Air in gas lines when in-

stalled

5. Depleted gas supply (pro-

pane/LP only)

6. ODS/pilot is clogged

7. Gas regulator setting is not

correct

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched

by any metal or tubing. Keep
ignitor cable dry

3. Replace ignitor cable
4. Replace ignitor
5. Replace pilot assembly

6. Replace pilot assembly
7. Install new alkaline battery in

electronic ignitor. Verify bat-
tery is installed correctly

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while in

PILOT position

4. Continue holding down con-

trol knob. Repeat igniting op-
eration until air is removed

5. Contact local propane/LP gas

company

6. Clean ODS/pilot (see Cleaning

and Maintenance, page 30) or
replace ODS/pilot assembly

7. Replace gas regulator

OBSERVED PROBLEM

When ignitor button is pressed,
there is no spark at ODS/pilot

When ignitor button is pressed,
there is spark at ODS/pilot but no
ignition

Advertising