Troubleshooting – Desa CGCF10PR User Manual

Page 34

Advertising
background image

www.desatech.com

112462-01C

34

WARNING: If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

Operating fireplace where impurities in air exist may create odors. Cleaning supplies,

paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes.
These fumes may mix with combustion air and create odors. These odors will disappear over time.

POSSIBLE CAUSE

1. Battery is not install. Battery

power is low

1. Metal expanding while heat-

ing or contracting while
cooling

1. Fireplace burning vapors

from paint, hair spray, glues,
cleaners, chemicals, new car-
pet, etc. (See IMPORTANT
statement above)

2. Low fuel supply (propane/LP

only)

3. Gas leak. See Warning

statement at top of page

1. Not enough fresh air is avail-

able

2. Low line pressure

3. ODS/pilot is partially

clogged

1. Gas leak. See Warning

statement at top of page

2. Control valve defective

1. Foreign matter between con-

trol valve and burner

2. Gas leak. See Warning

statement at top of page

REMEDY

1. Replace 9-volt batteries in re-

ceiver and remote control

1. This is common with most

fireplaces. If noise is exces-
sive, contact qualified service
person

1. Open window to ventilate

room. Stop using odor causing
products while fireplace is
running

2. Refill supply tank (propane/LP

only)

3. Locate and correct all leaks

(see Checking Gas Connec-
tions,
page 19)

1. Open window and/or door for

ventilation

2. Contact local natural or pro-

pane/LP gas company

3. Clean ODS/pilot (see Cleaning

and Maintenance, page 30)

1. Locate and correct all leaks

(see Checking Gas Connec-
tions
, page 19)

2. Replace control valve

1. Take apart gas tubing and re-

move foreign matter

2. Locate and correct all leaks

(see Checking Gas Connec-
tions
, page 19)

OBSERVED PROBLEM

Remote does not function (Re-
mote-Ready Models Only)

Fireplace produces a clicking/
ticking noise just after burners
are lit or shut off

Fireplace produces unwanted
odors

Fireplace shuts off in use (ODS
operates)

Gas odor even when control knob
is in OFF position

Gas odor during combustion

TROUBLESHOOTING

Continued

Advertising
This manual is related to the following products: