CIRCUTOR DHB Series User Manual

Page 18

Advertising
background image

18

Table 2

dISP

Parameter

symbol

Description

Range of changes

d_P

Minimal position of the decimal point

when displaying the measured value

- display format. This parameter is not

taken into consideration during the

CoUntH and HoUr modes.

0.0000 – 0
00.000 – 1
000.00 – 2
0000.0 – 3
00000 –

4

CoLdo

Display colour, when the displayed

value is less than CoLLo.

rEd – red
grEEn – green
orAnG -orange

CoLbE

Display colour, when the displayed

value is higher than CoLLo and less

than CoLHi.

CoLuP

Display colour when the displayed value

is higher than CoLHi

CoLLo

Lower threshold of colour change

-19999..99999

CoLHi

Upper threshold of colour change

-19999..99999

ovrLo

Lower threshold of the display nar-

rowing. Values below the declared

threshold are signaled on the display by
the symbol.

- - - - -

.

-19999..99999

ovrHi

Upper threshold of display narrowing.

Values above the declared threshold are
signaled on the display by the symbol.

- - - - -

.

-19999..99999

Table 3

Ind

Parameter

symbol

Description

Range of changes

IndCp

Number of points of the individual char-
acteristic. For a value less than 2, the
individual characteristic is switched off.
The number of segments is the number
of points decreased of one.
The individual characteristic is not taken
into consideration in the HoUr modes.

1...21

Xn

The point value for which we will expect

Yn (n-point number)

-19999...99999

Yn

Expected value for Xn.

-19999...99999