3.6. Power supply

The D12 utilizes an autosensing switch mode power supply for mains
voltages 115/230 V, 50 – 60 Hz (Optional 100/200 V) and
overvoltage protection.

Where voltages outside of this range are present, a self-resetting
protective circuit responds quickly to isolate the internal amplifier power
supply leaving only a supervisory circuit to monitor the mains voltage.

The display will clearly indicate the fault and voltage value.

The supervision circuit is self-resetting.

The associated voltage ranges and/or the guaranteed (nominal)
operating ranges are listed in the following table.

Voltage range

Status

0 – 98 V

Undervoltage

98 – 134 V

110/115/120 V operation

134 – 195 V

Undervoltage

195 – 265 V

220/230/240 V operation

265 – 400 V

Overvoltage

Tab. 2: Voltage ranges 115/230 V

To prevent the D12 from cycling on and off with fluctuating mains
power supply voltages, the switching thresholds are delayed and about
4% apart from the border of the voltage range (hysteresis).

Voltage range

Status

0 – 85 V

Undervoltage

85 – 117 V

100 V operation

117 – 170 V

Undervoltage

170 – 234 V

200 V operation

234 – 400 V

Overvoltage

Tab. 3: Voltage ranges 100/200 V

D12 Amplifier, Hardware manual

(4.9 EN)

Page 10 of 28