Connections, Mains panel, Mains power connection [8 – d&b D12 Hardware User Manual

Page 15: Fuse protection [9 (a/b), Warning, Important, R isk o f elect ric shock do not open

Advertising
background image

5. Connections

OUT A

OUT B

INPUT

LINK

CH B

ANALOG

DIGITAL

AES/EBU

CH A

ANALOG

SERVICE

REMOTE

VOLTAGE SEE LABEL
~ 50/60 Hz
1400 W

CAUTION

R ISK O F ELECT RIC SHOCK

DO NOT OPEN

www.dbaudio.com

MAINS SUPPLY

RISK OF FIRE - REPLACE FUSE AS MARKED

T10A H / 250 V

FUSE

T10A H / 250 V

FUSE

Made in Germany

[14a]

[9b]

[8]

[9a]

[12]

[13]

[15(a/b/c)]

[10] [11]

Mains panel

I/O panel

[14b]

Fig. 8: D12 Connections

5.1. Mains panel

SERVICE

REMOTE

VOLTAGE SEE LABEL
~ 50/60 Hz
1400 W

CAUTION

R ISK O F ELECT RIC SHOCK

DO NOT OPEN

www.dbaudio.com

MAINS SUPPLY

RISK OF FIRE - REPLACE FUSE AS MARKED

T10A H / 250 V

FUSE

T10A H / 250 V

FUSE

Made in Germany

[9b]

[8]

[9a]

[10] [11]

Fig. 9: D12 Mains panel

A PowerCon mains connector

[8] is fitted on the rear panel and an

appropriate mains lead is supplied.

Two RJ45

[10] connectors are also provided for the D12 REMOTE

functions.

A D-SUB-9 SERVICE connector

[11] is fitted which allows operating

software and loudspeaker configuration updates to be loaded into the
unit.

5.1.1. Mains power connection [8]

WARNING!

Only connect the D12 to mains power supplies with a
ground conductor (protective earth).

Make absolutely sure that earth is connected correctly.

IMPORTANT!

Before connecting the device to mains voltage, check that the mains
voltage and frequency corresponds to the specifications on the
configuration sticker on the rear of the D12.

5.1.2. Fuse protection [9 (a/b)]

WARNING!

If a fuse has failed disconnect the D12 from the mains
power supply before replacement.

Only use a fuse of the correct type – 5 x 20 mm/high
breaking capacity - and nominal current value. The
current value can be read from the rear mains panel
next to the respective fuse.

The mains fuses are located above the PowerCon socket and fulfill a
purely protective function in case of a device fault. They do not serve as
an overload protection.

In 200/230 V operation the upper fuse works only

[9a]. In 100/115 V

operation both fuses are working

[9a and b].

D12 Amplifier, Hardware manual

(4.9 EN)

Page 15 of 28