When the render stations are configured and OK is pressed on the Configure dialog, Wall Control-red will
connect to the render station. When the render stations are connected Vision inputs assigned to render
stationswill become unavailable to the Vision application.

A configured render stations screen can be deleted by selecting its entry from the list in the Configure
dialog and pressing the Remove button. To completely remove a render stations both Screen A and Screen
B must be removed.

The IP Address of a render station assigned to a Vision input can be changed by selecting the entry from
the list and clicking the Modify button. The Vision input cannot be changed from the Modify dialog, and a
new entry must be created instead.

RSN870 Status

The status column indicates the connection status for each configured render station screen. The five
possible states are as follows:

Testing

Wall Control-red is in the process of testing all connections.

Offline

The render station has not been connected. All stations are shown as offline until they can be connected. It
may take up to twenty seconds for the status to change to the connected state.

Flash Error

The render station was successfully connected but the Vision card’s EDID could not be flashed. This may
be caused by a hardware issue or the use of an incorrect driver. When in this state the capabilities may be
reduced.

Screen Error

The render station was successfully connected but an initialisation error occurred. This may be caused by
an incorrect software or hardware configuration on the render station. When in this state the capabilities
may be reduced.

Connected

The render station was successfully connected and is ready for use.