VENTING INSTALLATION

INSTRUCTIONS

Continued

Note: Install
restrictor into
inner collar of
fireplace as
shown.

Venting with Two 90° Elbows

Vertical (V

1

)

Horizontal (H)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

Note: Vertical (V

1

) + Vertical (V

2

) = 40' max.

Figure 23 - Vertical Venting

Configuration Using Two 90° Elbows

(Vertical Round High Wind Termination

Shown)

45° Elbow

Vertical Venting

V = 40' max.

Figure 24 - Vertical Venting

Configuration With No Horizontal Run

(Vertical Round High Wind Termination

Shown)

Note: Install
restrictor into
inner collar of
fireplace as
shown.

45° Elbow

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been

tested and approved for elevations from 0-2000

feet (USA) and elevations from 0-4500 feet

(Canada).

When installing this fireplace at an elevation

above 2000 feet (in the USA), you may need to

decrease the input rating by changing the existing

burner orifice to a smaller size. Reduce input 4%

for each 1000 feet above sea level. Check with

your local gas company for proper orifice size

identification.

When installing this fireplace at an elevation

above 4500 feet (in Canada), check with local

authorities.

Consult your local gas company to help determine

the proper orifice for your location.

For assistance with any high altitude installation

contact DESA’s Customer Service Department at

1-866-672-6040.