X*ap rm – Junger Audio X*AP RM1 User Manual

Page 12

Advertising
background image

X*AP RM

1

8


Next page shows the Compressor parameters



Here another example for <EBU Meter>


In this case the <F-Keys> will control the program based loudness measurement process defined by
EBUR128. The display represents the measurements of Integrated- / Short Term- and Momentary-
Loudness
as well as the LRA (Loudness Range) [LU] and Max TPL [dBTP],
the Maximum True Peak level.

The measure for the EBU Meter display is [LUFS] (Loudness Units Full Scale) as long as not defined
differently.

For details pls. refer to the EBU-Tech 3341 document.

MENU

ESC

Compressor On Reference Level[dB] Range[dB]

LFE

ALL On -18 8

Program 1

On -18 8

Ratio Processing

2/2

2.0 uni

uni

2.5

MENU

ESC

EBU R128 Integrated LRA Time
[LUFS] [LU] hh:mm:ss

Input -19.3 6.4
Output -23.2 5.8 00:12:15

Short Term Max TPL Momentary
[dBTP] Max

-19.7 -6.6 -12.0
-21.3 -5.0 -16.0

reset max Program 1