3.3 Fiber Port Testing
As shown in Figure 3.2, connect two ESML6-P3 units via their fiber ports. Then
attach a computer to any RJ45 port on each device and send the “ping” command
between the connected computers. If both computers get the command without
packet loss and the corresponding LINK/ACT indicators of the fiber ports flash, this
then shows the fiber ports under test are functioning correctly.
Figure 3.2 Fiber Port Testing
4 System Example
Figure 4.1 ESML6-P3 Typical System Application