2.3

Installation Method

2.3.1 DIN Rail Mount

•

Remove all packaging material.

•

Attach the device to a DIN rail.

•

Attach copper cables as required.

•

Insert the male power block (attached to the supplied in-line PSU) to the

female power socket on the device and tighten the terminal locking screws

using a flathead screw driver.


See Section 2.7 for LED status.

2.3.2 Wall-mount

•

Remove all packaging material.

•

Unscrew the DIN rail mounting plate from the switch taking special care to

retain the 3 screws using a Phillips No.1 or No.2 screwdriver.

•

Attach the supplied wall mount plates to the switch using the screws that

have just been removed from the DIN rail mounting plate with a Phillips

No.1 or No.2 screwdriver.

•

Position the unit on the required, flat surface and secure with screws via the

mounting plate holes. Screws are not provided.

•

Attach copper cables as required.

•

Insert the male power block (attached to the supplied in-line PSU) to the

female power socket on the device and tighten the terminal locking screws

using a flathead screw driver.


See Section 2.7 for LED status.

2.4 Ethernet RJ45 Connections

Each RJ45 port is adaptive and supports auto MDI/MDI-X connection. They can be
connected by straight through or cross-over cables to terminal devices, servers, hubs or
other switches. Each switch supports IEEE802.3x and IEEE802.3ab so the optimum
transmission mode (either half-duplex or full-duplex) and data rate (10Mbps, 100Mbps
or 1000Mbps) will be selected automatically.