Symbology Options Overview

Enable All Symbologies — allows the scanner to auto-discriminate between

all the symbologies in this list. Use this selection only if you must constantly
read a wide variety of symbologies. Turn to the following pages for
enabling additional symbology specific options.

Disable All Symbologies — disables all symbologies

1

. The scanner will only

recognize the programming labels contained in this manual while you are
in Programming Mode.

Enable UPC/EAN — tells the scanner to recognize UPC-A, UPC-E, EAN-

8, and EAN-13. If you enable this symbology, additional options for
symbology expansion and reading add-ons are available. Allows selection
of expansion and add-on options.

Enable Code 39 — selects Code 39 as an active symbology. Allows selection

of Check Digit, Start/Stop and Single Digit options.

PharmaCode 39 — is a symbology subset of Code 39. Enabling PharmaCode

39 selects this special Italian code as the active Code 39 symbology
(superceding standard Code 39 features).

NOTE

Standard Code 39 must be enabled before PharmaCode can be
enabled.

Enable Interleaved 2 of 5 — selects Interleaved 2 of 5 as an active

symbology. Allows change of Check Digit or label format (fixed
or variable length) options.

Enable Standard 2 of 5 — selects Standard 2 of 5 as an active

symbology. Options for this symbology are similar to Inter-
leaved 2 of 5 features.

1

Code 128 is always active for the purpose of reading programming bar code labels; however,
the scanner does not transmit data to the host when in Programming Mode. Scanning the
DISABLE ALL SYMBOLOGIES label will disable Code 128 transmission to the host.