Crossovers, Wiring diagram, Fuses and protection circuits – KLING & FREITAG K&F Line 212-9 User Manual

Page 27: Crossovers 27, 1 wiring diagram, 2 fuses and protection circuits

Advertising
background image

User's Manual

LINE 212-6 / LINE 212-9

KLING & FREITAG GMBH ©2003 - 2005

Version 4.1, 23.03.2006

Seite 27 von 37

12.

Crossovers

12.1

Wiring Diagram

FUSE :

250 V T 4A

FUSE :

250 V T 4A

1-

1+

2+
2-

1-

1+

2+
2-

+

+

-

-

+

+

-

-

HF

HF

LF 1

LF 1

LF 2

LF 2

+

+

-

-

Pin assignment Speakon NL4

+ - / /

'IN'

1+ 1-

2+ 2-

'OUT'

parallel with 'IN'

12.2

Fuses and Protection Circuits

The LINE 212 is equipped with protection circuits, which cut off the signal current when
highly overloaded - for the 1.5" high frequency speaker as well as for the crossover. If
the high frequency speaker of the Line 212 turns off, reduce the volume. After a few
seconds, it will turn back on automatically.

If there is operating trouble, the low-mid crossover circuits are protected with fuses.
Blown fuses can only be replaced with fuses with the following specifications:

250V T4L (DIN EN 60127-2-3)
Do not use fuses with different specifications and do not try to bypass the fuse as this
may cause fire hazard.

Warning