c) The LED stays permanently red, if…

…the protection circuitry of the integrated power amplifier cuts in and as a
result, no further signal reaches the speaker (Protect Mode).

The protection circuitry switches off the integrated power amplifier,…

− …if the temperature of the amplifier module is too high. As soon as

the temperature falls below the critical value, the amplifier module is
switched on again automatically. Excessive temperatures can be
caused for example by inadequate ventilation of the heat sink. Make
sure that the heat sinks are not covered or positioned directly against a
wall.

− …if the output impedance is too low or in the case of a short circuit,

caused for example by a defective chassis or a faulty component on
the crossover.

− …if the amplifier has an internal fault. The SP amplifier module checks

that all is functioning correctly during operation. As soon as a fault be-
comes apparent, the module switches into protect mode. If only one
module has a fault, the input signal is attenuated by 70 dB, to prevent
damage to the other module.

Measures to be taken when LED is red:

Fault

Measure

Function

LED remains red or flickers
continually during opera-
tion.

Reduce output level on mixer until the
LED goes out or flickers only occasion-
ally

Limiter

No or too low output sig-
nal, LED shows red in spite
of reduced mixer output
level.

Allow to cool. The amplifier module
switches itself on after a few minutes.
Provide sufficient ventilation.

Temperature
protection

No or too low output sig-
nal, LED stays red after
cooling down.

Have loudspeaker checked by
authorized service technician.

Other
protection

Output signal is too low, no
bass frequencies or no high
frequencies.

Have loudspeaker checked by
authorized service technician.

Other
protection

7) AC MAINS ‘IN’

Connect this PowerCon socket using the mains cable supplied to a max. 16 A fused
mains socket, paying particular attention to the stated mains voltage! Connection
to an incorrect mains voltage can result in irreparable damage!

8) AC MAINS ‘OUT’

Socket for connection to further equipment such as further speakers with SP mod-
ule. Use only connection cables, which conform to your national safety regul

Use only connection cables, which conform to your national safety regul

Use only connection cables, which conform to your national safety regul

Use only connection cables, which conform to your national safety regula-

a-

a-

a-

tions.

tions.

tions.

tions.
Maximum power consumption:

230 V: 10 A / 2300 W

110 V: 10 A / 1150 W

Important