Matrix Setup

• To use the R184 units as a matrix, one unit is designated as a master unit, and the other
units as slave units.
• Record the ID’s of the units, noting which unit will be the master unit.
• Mount the units where desired, realizing that the outputs of each of the slave units MUST be
routed to one of the sixteen inputs on the master unit. The master unit output is then
connected to the device receiving the RF input selected.
• After mounting, connect the RS485 cable plugs to the master and slave units. Remember to
connect the end plug on the cable to the unit designated the master unit.
• Plug in the power supplies to the rear panels of the units, and then to power outlets.
• Refer to the software instructions to set up the software for the matrix units.