Power consumption measurement – NEXCOM NISE 3100eP2 User Manual

Page 73

Advertising
background image

Copyright © 2009 NEXCOM International Co., Ltd. All Rights Reserved.

60

NISE 3100e, NISE 3100eP2, NISE 3150e User Manual

Appendix A: Power Consumption

Power Consumption Measurement

Purpose
The purpose of the power consumption test is to verify the power dissipa-
tion of the system and the load of the power supply.

Test Equipment
PROVA CM-07 AC/DC CLAMP METER

Device Under Test
DUT: Sys #1 / Sys #2

Test Procedure
1. Power up the DUT then boot Windows XP.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.

Test Data

Sys #1

Sys #2

+19V

+19V

Full-Loading Mode

2.1A

2.3A

Total

39.9W

43.7W

Standby Mode

1.1A

1.2A

Total

20.9A

22.8W