C: w, Ppendix, Atchdog – NEXCOM NISE 3100eP2 User Manual
Page 75: Imer, Etting

Copyright © 2009 NEXCOM International Co., Ltd. All Rights Reserved.
62
NISE 3100e, NISE 3100eP2, NISE 3150e User Manual
Appendix C: Watchdog Timer Setting
A
ppendix
C: W
AtChdog
t
imer
S
etting
;*Enter the MB PnP mode with 0x87, 0x01, 0x55, 0x55
mov
dx, 2eh
mov
al, 87h
out
dx, al
mov
dx, 2eh
mov
al, 01h
out
dx, al
mov
dx, 2eh
mov
al, 55h
out
dx, al
mov
dx, 2eh
mov
al, 55h
out
dx, al
;*Set LDN=0x07 point to the WDT function
mov
dx, 2eh
mov
al, 07h
out
dx, al
mov
dx, 2fh
mov
al, 07h
out
dx, al
;*Setup configuration register 0x72, if set 0c0h is second, set 40h is
minute(WDT output through KRST)
mov
dx, 2eh
mov
al, 72h
out
dx, al
mov
dx, 2fh
mov
al, 0c0h
out
dx, al
;*Setup WDT time-out value. this demo code is used to program the tim-
out value with 4 sec.
mov
dx, 2eh
mov
al, 73h
out
dx, al
mov
dx, 2fh
mov
al, 4
out
dx, al
;*Exit the MB PnP Mode
mov
dx, 2eh
mov
al, 02h
out
dx, al
mov
dx, 2fh
mov
al, 02h
out
dx, al