Service procedures, Warning – Desa BY150ECA User Manual

Page 10

Advertising
background image

10

102424

SERVICE

PROCEDURES

WARNING

!

Upper Shell Removal

1. Remove screws along each side of

heater using 5/16" nut-driver. These
screws attach upper and lower shells
together.

2. Lift upper shell off.
3. Remove fan guard.

Fan

IMPORTANT:

Remove fan from motor

shaft before removing motor from
heater. The weight of the motor resting
on the fan could damage the fan pitch.

1. Remove upper shell (see above).
2. Use 1/8" allen wrench to loosen set-

screw which holds fan to motor
shaft.

3. Slip fan off motor shaft.
4. Clean fan using soft cloth moistened

with kerosene or solvent.

5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place

fan hub flush with end of motor shaft
(see Figure 7).

7. Place setscrew on flat of shaft.

Tighten setscrew firmly (4.5-5.6
n-m/40-50 inch-pounds).

8. Replace fan guard and upper shell.

Fan

Setscrew

Motor
Shaft

Motor

Flush

Air Output, Air Intake, and
Lint Filters

1. Remove upper shell (see above).
2. Remove filter end cover screws

using 5/16" nut-driver.

3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter (see

Preventative Maintenance Schedule,
page 8).

6. Replace filter end cover.
7. Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters.

Figure 7 - Fan Cross Section

Figure 6 - Upper Shell Removal

Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.

Upper
Shell

Figure 8 - Air Output, Air Intake, and Lint Filters

Fan Guard

Air Intake Filter

Air Output Filter

Filter End Cover

Lint Filter

Fan
Guard

Advertising