Pump rotor – Desa BY150ECA User Manual

Page 13

Advertising
background image

13

102424

100 ROTOR-Domestic

PFA/P 059A

Pump Rotor

(Procedure if rotor is binding)

1. Remove upper shell (see page 10).
2. Remove filter end cover screws

using 5/16" nut-driver.

3. Remove filter end cover and air

filters.

4. Remove pump plate screws using

5/16" nut-driver.

5. Remove pump plate.
6. Remove rotor, insert, and blades.
7. Check for debris in pump. If debris

is found, blow out with com-
pressed air.

8. Install insert and rotor.
9. Check gap on rotor. Adjust to

.076/.101 mm (.003"/.004") if
needed (see Figure 17).

Note:

Rotate rotor one full turn to

insure the gap is .076/.101 mm
(.003"/.004") at tightest position.
Adjust if needed.

10.Install blades, pump plate, air filters,

and filter end cover.

11.Replace fan guard and upper shell.
12.Adjust pump pressure (see page 11).

Note:

If rotor is still binding, proceed as

follows.

13.Perform steps 1 through 6 above.
14.Place fine grade sandpaper (600 grit)

on flat surface. Sand rotor lightly in
“figure 8” motion four times (see
Figure 18).

15.Reinstall insert and rotor.
16.Perform steps 10 through 12 above.

Fan Guard

Filter End Cover

Air Intake Filter

Pump Plate

Blade

Air Output Filter

Rotor

Insert

Figure 16 - Rotor Location

Sandpaper

Figure 18 - Sanding Rotor

Figure 17 - Gap Adjusting Screw Locations

Gap Adjusting Screw

Gap Adjusting Screw

.003"/.004" Gap
Measured With
Feeler Gauge

Rotor

Blade

Advertising