Specifications, Replacement parts and accessory, Wiring diagram – Desa BY150ECA User Manual

Page 14

Advertising
background image

14

102424

Output Rating (Btu/Hr.)

100,000

150,000

Fuel

Use Only Kerosene or No. 1 Fuel Oil

Fuel Tank Capacity (Liters/U.S. Gal.)

34/9.0

51/13.5

Fuel Consumption (Liters/Gal. Per Hr.)

2.8/.76

4.1/1.1

Electric Requirements

120 V/60 Hz (Same All Models)

Amperage (Normal Run)

4.0

4.4

Hot Air Output (CMM/CFM)

13.6/480

14.2/500

Motor RPM

3450

3450

Motor HP

1/4

1/4

Approximate Shipping Weight (KG/Pounds)

27/60

31/68

Approximate Heater Weight without Fuel

(KG/Pounds)

23/51

26/57

SPECIFICATIONS

Purchase accessories and parts
from your local dealer.

REPLACEMENT

PARTS AND

ACCESSORY

White

Brown

Blue

Green/Yellow

120V/60Hz

Photocell

Spark Plug

Ignitor

Flame-

Out

Control

B

Reset

Button

R

Red

Motor

Blue

White

Blue

White

Green/

Yellow

White

Red

Red

Green/

Yellow

Terminal

Board

Red

Relay

Black

WIRING

DIAGRAM

AIR GAUGE KIT - HA1180

Special tool to check pump pressure.