Ventilation, Operation, Warning – Desa BY150ECA User Manual

Page 7

Advertising
background image

7

102424

WARNING

!

VENTILATION

Continued

Follow the minimum fresh, outside air ventilation
requirements. If proper fresh, outside air ventilation is not
provided, carbon monoxide poisoning can occur. Provide
proper fresh, outside air ventilation before running heater.

OPERATION

WARNING

!

Review and understand the warnings in the Safety Informa-
tion Section, pages 2 and 3. They are needed to safely
operate this heater. Follow all local codes when using this
heater.

To Start Heater

1. Follow all ventilation and safety information.

2. Fill fuel tank with kerosene or No. 1 fuel oil.

3. Attach fuel cap.

4. Plug power cord of heater into standard 120 volt/60 hertz, grounded (earthed)

outlet. Use an extension cord if needed. Use only a three-prong, grounded
(earthed) extension cord.

Extension Cord Wire Size Requirements

Up to 30.5 meters (100 feet) long, use 1.0 mm

2

(16 AWG) conductor

30.6 to 61 meters (101 to 200 feet) long, use 1.5 mm

2

(14 AWG) conductor

Heater will start when power cord is plugged into outlet. If not, push in flame-
out control reset button (see Figure 5).

Figure 5 - Flame-Out Control Reset Button

Flame-Out Control
Reset Button

Provide a fresh air opening of at least 2800 square cm (three square feet) for each
100,000 Btu/Hr rating. Provide extra fresh air if more heaters are being used.

Example:

A 150,000 Btu/Hr heater requires one of the following:

• a two-car garage door raised 15.24 cm (six inches)
• a single-car garage door raised 22.86 cm (nine inches)
• two, 76.20 cm (thirty-inch) windows raised 30.48 cm (twelve inches)