065-7310F 8-Port 100BaseFX Fiber Switches

10 User Manual

Installation

This chapter presents step-by-step installation instructions for

The Signamax 8-port 100BaseFX fiber switch.

Selecting a Site for the Switch

♦ As with any electronic device, you should place the

Switch where it will not be subjected to extreme

temperatures, humidity, or electromagnetic interference.

Specifically, the site you select should meet the

following requirements:

♦ The room temperature should be between 32 and 104

degrees Fahrenheit (0 to 40 degrees Celsius).

♦ The relative humidity should be less than 90 percent,

non-condensing.

♦ Surrounding electrical devices should not exceed the

electromagnetic field (RFC) standards for IEC 801-3,

Level 2 (3V/M) field strength.

♦ Make sure that the switch receives adequate

ventilation. Do not block the ventilation holes on the

side of the switch or the fan exhaust port on the rear of

the switch.

♦ The power outlet should be within 6 feet (1.8meter) of

the switch.