Installation
This chapter gives step-by-step installation instructions for 
the Converter. 
 
Selecting a Site for the Equipment 
As with any electric device, you should place the equipment 
where it will not be subjected to extreme temperatures, 
humidity, or electromagnetic interference. Specifically, the 
site you select should meet the following requirements: 
 
 The ambient temperature should be between 14 and 140 degrees
Fahrenheit (-10 to 60 degrees Celsius).
 The relative humidity should be less than 95 percent, non-condensing. 
 Surrounding electrical devices should not exceed the electromagnetic field 
(RFC) standards.
 Make sure that the equipment receives adequate ventilation. Do not block
the ventilation holes on each side of the equipment.
 The power outlet should be within 1.8 meters of the product.
Wiring Diagram 
Field Wiring Terminal Markings: Use Copper Conductors 
Only, 140/167℉ (60/75℃), wire range 12-24 AWG, torque 
value 7 lb-in.