Relay/high drive outputs – Zilog Z8F0411 User Manual

Page 27

Advertising
background image

MDS General-Purpose Board Development Kit

User Manual

UM016905-1207

MDS-GP Board Features

22

Relay/High Drive Outputs

Figure 10

displays the two relays and six high-drive outputs included on

the MDS-GP board. By default, jumper J27 is set to route the 9 V to 12 V
DC power input to both the relays and the high-drive outputs. If 5 V DC is
used to power the MDS-GP board, then connect Pin 2 and Pin 3 on
jumper J27 to apply 5 V DC on the high-drive outputs.

The two relays installed on the board are 12 V DC types. These relays are
only supported when the 9 V to 12 V DC power supply input is used (see

Figure 10

).

J26

LCD_Sel

Data Control for
LCD

OFF

Install this jumper to select I

2

C

control of the LCD control pins.

J28

BL

LCD BackLight

1, 2

This jumper selects the LCD back
light control. Jumper pins 2, 3 for
software control of backlight.

J29

ADC_POT

POT Select

ON

This jumper connects the

on-board potentiometer to one
ADC input.

Table 3. Miscellaneous Jumper Settings (Continued)

Jumper

Symbol

Name

Factory
Default

Function

Advertising