eZ80F92 Development Kit

User Manual

UM013911-0607

Operational Description

13

Table 2. eZ80Acclaim!

®

Development Platform

Peripheral Bus Connector Identification—JP1*

Pin #

Symbol

Signal Direction

Active Level

eZ80F92 Signal

2

1

A6

Bidirectional

Yes

2

A0

Bidirectional

Yes

3

A10

Bidirectional

Yes

4

A3

Bidirectional

Yes

5

GND

6

V

DD

7

A8

Bidirectional

Yes

8

A7

Bidirectional

Yes

9

A13

Bidirectional

Yes

10

A9

Bidirectional

Yes

11

A15

Bidirectional

Yes

12

A14

Bidirectional

Yes

13

A18

Bidirectional

Yes

14

A16

Bidirectional

Yes

15

A19

Bidirectional

Yes

Notes:
1. For the sake of simplicity in describing the interface, Power and Ground nets are omitted from

this table. The entire interface is represented in the eZ80F92 Module Schematics

on pages 65

through 67

.

2. The Power and Ground nets are connected directly to the eZ80F92 device.
3. External capacitive loads on RD, WR, IORQ, MREQ, D0–D7 and A0–A23 should be below 10 pF

to satisfy the timing requirements for the eZ80

®

CPU. All unused inputs should be pulled to

either V

DD

or GND, depending on their inactive levels to reduce power consumption and to

reduce noise sensitivity. To prevent EMI, the EZ80CLK output can be deactivated via software in
the eZ80F92’s Peripheral Power-Down Register.