AMETEK Lx Series II User Manual
Page 192
Advertising

User Manual
Lx / Ls Series II
188
SVF 601 Tests
– Revision F
SVF601
Power Failure - One Phase
Condition
Duration (s)
Run at 400, Repeat at 360, 600 and 800 Hz
A
100 msec
52
B
500 msec
54
C
3 sec
66
D
7 sec
86
SVF 602 Tests
– Revision F
Not applicable for single-phase
EUT‟s.
SVF 603 Tests
– Revision F
SVF603
Power Failure
– Phase Reversal
Condition
Duration (s)
Run at 400, Repeat at 360, 600 and 800 Hz
N/A
Use physical L-N connection reversal
Apply Vnom = 115 V, Fnom = 400 Hz
1800