4.17 Source Subsystem - Frequency
This subsystem programs the output frequency of the AC source.
Subsystem Syntax
[SOURce:]
FREQuency
[:CW | :IMMediate] <n>
Sets the frequency
:MODE <mode>
Sets frequency mode (FIX|STEP|PULS|LIST|SENS|EXT)
:SLEW
[:IMMediate] <n> | INFinity
Sets the frequency slew rate
:MODE <mode>
Sets frequency slew mode (FIX|STEP|PULS|LIST)
:TRIGgered <n> | INFinity
Sets the triggered frequency slew rate
:TRIGgered <n>
Sets the triggered frequency
FREQuency
This command sets the frequency of the output waveform.
Command Syntax
[SOURce:]FREQuency[:CW|:IMMediate]<NRf+>
Parameters
45 to 5000
Unit
HZ (Hertz)
*RST Value
60 Hz
Examples
FREQ 50
Query Syntax
[SOURce:]FREQuency?
Returned Parameters
<NR3>
Related Commands
FREQ:MODE FREQ:SLEW
FREQuency:MODE
This command determines how the output frequency is controlled. Available modes are:
FIXed
The output frequency is unaffected by a triggered output transient. The
clock source is the internal controller timebase.
STEP
The output frequency is programmed to the value set by
FREQuency:TRIGgered when a triggered transient occurs.
PULSe
The output frequency is changed to the value set by
FREQuency:TRIGgered for a duration determined by the pulse
commands.
LIST
The output frequency is controlled by the frequency list when a triggered
transient occurs.
SENSe
External sync or line sync clock mode. The frequency is synchronized to
the external sync or line sync frequency. See Lx/Ls user manuals for
sync operation details.
EXTernal
External clock mode. This mode is used on an Lx/Ls unit with the
–LKS
option to sync to a master Lx/Ls unit.
Command Syntax
[SOURce:]FREQuency:MODE<mode>
Parameters
FIXed | STEP | PULSe | LIST | SENSe | EXTernal
*RST Value
FIXed
Examples
FREQ:MODE FIX
Query Syntax
[SOURce:]FREQuency:MODE?
Returned Parameters
<CRD>
Related Commands
FREQ FREQ:TRIG